Categories
Body

nsxb20110a.pdf

Water Leak Test
NOTE: When the following parts have been replaced or
removed, and or the roof side lock unit, door glass and
door have been adjusted, this water leak test should be
done.
• Roof side seals
• Roof side lock units
• Front and rear pillar seals
• Door and door glass
1. Make sure that the roof is locked securely.
2. Raise the glass fully, and close the doors.
3. Spray water over the roof and on the sealing area
as shown.
NOTE:
• Adjust the water pressure as shown.
• Do not squeeze the tip of the hose.
12 mm (0.47 in)
HOSE
0.5 m (1.6 ft)
-HOSE
SEALING
AREA
4. Check for water leaks.
5. If there are leaks, recheck the work performed, and
recheck the door glass, seal, and retainer adjust-
ments.