Lighting System
Daytime Running Lights Control Unit Input Test (Canada)
Remove the glove box lower panel and glove box.Dis-
connect the 4-P and 8-P connectors from the daytime
running lights control unit.
Inspect the connector terminals to be sure they are all
making good contact.
If the terminals are bent, loose, or corroded, repair
them as necessary, and recheck the system.
If the terminals look OK, make the following input tests
at the connector.
If any test indicates a problem, find and correct the
cause, then recheck the system.
If all the input tests prove OK, the control unit must
be faulty; replace it.
4-P CONNECTOR
DAYTIME RUNNING LIGHTS
CONTROL UNIT (Canada)
8-P CONNECTORView from wire side
GRN/YELGRN/RED
Daytime Running Lights Control Unit Input Test (Canada)
Remove the glove box lower panel and glove box.Dis-
connect the 4-P and 8-P connectors from the daytime
running lights control unit.
Inspect the connector terminals to be sure they are all
making good contact.
If the terminals are bent, loose, or corroded, repair
them as necessary, and recheck the system.
If the terminals look OK, make the following input tests
at the connector.
If any test indicates a problem, find and correct the
cause, then recheck the system.
If all the input tests prove OK, the control unit must
be faulty; replace it.
4-P CONNECTOR
DAYTIME RUNNING LIGHTS
CONTROL UNIT (Canada)
8-P CONNECTORView from wire side
GRN/YELGRN/RED