Starting System
CAUTION: Disconnect the ground cable from the bat-
tery before removing the starter. SOLENOID
PLUNGER
Inspection, page 23-86
STARTER
SOLENOID
Test, page 23-81
OVERRUNNING
CLUTCH ASSEMBLY
BRUSH HOLDER
ARMATURE
IDLER GEAR
PINION GEAR
END COVER
O-RING
Replace.
FIELD WINDING/
ARMATURE HOUSING
Test, page 23-86
IDLER GEAR
SOLENOID HOUSING
HARNESS CLIP BRACKET
STEEL BALL
When reassembling
install steel ball
from clutch side.
MOLYBDENUM
DISULFIDE
ROLLER BEARINGS
and CAGE
Set these aside so you won’t lose them.
MOLYBDENUM DISULFIDE
OVERRUNNING CLUTCH ASSEMBLY
Inspection, page 23-87
GEAR HOUSING
MOLYBDENUM
DISULFIDE
Starter Overhaul
BRUSH HOLDER
Test, page 23-83 BRUSH
Inspection,
page 23-83
ARMATURE
Inspection and Test,
page 23-84
O-RING
Replace.